HAI Modules
10A06
16 Zone Expansion Module
|
|
- Expands HAI Systems from 16 to 32 fully configurable input zones.
- Terminals are provided for each of the 16 additional zones.
- Zones can be programmed for buglary, fire, temperature or auxiliary inputs.
- Includes mounting hardware and cable for attachment.
|
|
|
22A00-1
OnliLT Zone Expansion Module
|
| This module expands the OmniLT by adding 16 zones and 8 voltage outputs with overload
protection and reset. The module comes with mounting hardware and cable to attach to the
OmniLT controller.
The 16 zones can be programmed for burglary, temperature or auxiliary inputs. The 8 outputs
have individual overload protection, with overload indicator and reset button. |
|
|
10A07
4 Channel Relay Module
|
|
- 4 separate relays convert HAI voltage outputs to form C relay contacts.
- 24 VDC Contacts are rated at 5 amps.
- LED indicators show which relays are energized.
| |
|
19A00
8 Channel Relay Module
|
 |
- 8 separate relays convert HAI voltage outputs to form C relay contacts.
- 24 VDC Contacts are rated at 5 amps.
- LED indicators show which relays are energized.
| |
|
10A11
Two Way Voice Module
|
|
- Allows for 2-way voice communications between the premises and central station after an alarm event.
- Can be used to set up as an internal paging/intercom system.
- Connects to the HAI controller board and outboard speaker/microphones.
| | After an audible alarm, the module allows the central station to control the listen/talk mode. For silent alarms, the module allows listen in only. User can also access listen/talk features from any touch-tone phone, both local and remote. Additionally, the 10A11 can be set up to announce alarms inside the premises using HAI's built-in voice.
| |
|
31A00-7 31A00-8
Indoor/Outdoor Temperature & Temperature/Humidity Sensors
|
|
- Indoor/Outdoor Temperature Sensor (31A007).
- Indoor/Outdoor Temperature/Humidity Sensor (31A008).
- Coated with sealant to resist moisture.
- Includes stainless steel mounting screws.
- New version never needs calibration!
-
Inside view
- Dimensions: 2 3/4" x 2 3/4" x 1"
| | The Model 31A00-7 and Model 31A00-8 Indoor/Outdoor Temperature Sensor is used for sensing outdoor or indoor temperature. It is coated with a sealant to withstand outdoor moisture and features a new, high accuracy temperature sensor that doesn’t need calibration.
The temperature can be used to activate programs for controlling temperatures in attics, garages, greenhouses, basements, wine cellars, and coolers. The temperature can be displayed on the console or spoken over the telephone. It can also report, log, alert, or generate an alarm if the temperature reaches freeze conditions or if the temperature goes above the high setpoint or drops below the low setpoint programmed in the system.
The Model 31A00-8 also includes a Humidity Sensor that is used for reporting the outdoor or indoor relative humidity from 0 to 100 percent. High and low humidity limits can be set for taking action (i.e. turning on the bathroom vent fan, running a/c in de-humidification mode, turning on humidifier in heating mode, etc.) or reporting high or low humidity conditions in homes, greenhouses, wine cellars, coolers, humidors, etc. Controlling humidity is particularly helpful in combating the growth of mold in vulnerable areas of the home, such as bathrooms, basements, attics, etc.
| |
|
23A00-1
Indoor Surface Mount Temperature Sensor
|
| | Remote Temperature Sensors can be mounted in the conditioned space and the thermostat can be mounted remotely for protection from
tampering or for aesthetic reasons. Both models can be located up to 50 feet from the thermostat, using 24 gauge 2-conductor-plus-shield
wire. Remote Sensors must be mounted in the same locations appropriate for a thermostat for best performance (for example, on an inside
wall, free of draft from vents, away from sunlight, windows, etc.)
23A00-1 Remote Indoor Temperature Sensor / Surface: This small (2 W X 1.5 H X I D inches)
unit is mounted on the surface of the wall.
| |
|
23A00-2
Indoor Flush Mount Temperature Sensor
|
| | Remote Temperature Sensors can be mounted in the conditioned space and the thermostat can be mounted remotely for protection from
tampering or for aesthetic reasons. Both models can be located up to 50 feet from the thermostat, using 24 gauge 2-conductor-plus-shield
wire. Remote Sensors must be mounted in the same locations appropriate for a thermostat for best performance (for example, on an inside
wall, free of draft from vents, away from sunlight, windows, etc.)
23A00-2 Remote Indoor Temperature Sensor / Flush: This small unit slides into a 13/16" diameter hole in the wall. The 1 1/2" diameter metal disk is suspended 1/8" away from the wall in order to accurately measure room temperature. The metal disk may be painted.
| |
|
14A00-8
Water Temperature Sensor
|
| | The 14A00-8 is a temperature sensor used to monitor the temperature of pools, spas, aquatic ponds, and greenhouses. The temperature sensing device is potted in a stainless steel probe. It is designed specifically to monitor water temperature from the return/source and then report that information back to an HAI Omni Family controller. Supplied with stainless steel mounting screws and waterproof connectors.
| |
|
28A00-1 28A00-2
Speaker/Microphone Modules
|
| | The Model 28A00-1 and -2 is a speaker and microphone assembly that allows two-way communication with a central station after an alarm, paging and listening from an on-premises or remote phone, annunciation of alarm and zone by voice, and voice messaging*, when connected to a Two-Way Voice Module. It may be used outdoors in weather protected areas.
*Voice messaging not available on all systems
Two versions are available:
Model 28A00-1 Surface Speaker/Microphone Module Dimensions: 5 3/16" H x 5 3/16" W x 2 5/8 D
Model 28A00-2 Flush Speaker/Microphone Module Dimensions: 4 1/2" H x 4 1/2" W x 1 1/2" D (Protrudes only 1/2" when flush mounted)
| |
|
|