Sensor Probes
ELK-930
Dorbell & Telephone Ring Detector
|
|
- Doorbell
- Detects Doorbell Activation Current.
- Inputs for Two Separate Pushbutton Locations.
- No Interference With Lighted Pushbuttons.
- Produces an Open Collector Output.
- Powered by the Doorbell Transformer.
- Telephone
- Detects Telephone Ringing Voltage.
- Provides an Open Collector Output that follows the ringing pattern.
- Small, Compact Size.
- Double Sided Foam Tape Provided For Mounting.
- Packaged in Reusable Poly Storage Box.
- Lifetime Limited Warranty.
- Max Input on Doorbell Boards: 24 Volts AC Nominal
- Max Output: 40mA @ 12 Volts D.C.
- Doorbell Detection Current: 900mA min.
- Size: 3.4" x 2.75" x .625"
-
Installation Manual(PDF)
-
930 to 960 Connection Sample Diagrams(PDF)
| | The ELK-930 performs three functions. It can detect ring activation from one or two doorbell buttons and a single telephone line. It conveniently isolates the voltage and current and produces an open collector (pull to ground) output which can be used to trigger an automation controller, relay, timer, etc. The circuit is pre-scored so that the individual detectors may be snapped off (separated) from each other.
The ELK-930 Doorbell Detector monitors the current draw of a doorbell and produces an open collector output when the pushbutton is pressed and the doorbell draws 900mA or more. This open collector output can be used to trigger an automation controller input that utilizes high to low switching (pull to ground) for activation. The ELK-930 Telephone Ring Detector monitors the voltage on the telephone line and produces an open collector output (pull to ground) when the telephone ringing voltage is approximately 50 Volts or greater. The output follows the ringing pattern.
| |
|
502
Mini-Clik Rain Sensor |
|
- Automatically shuts off sprinkler systems when it rains
- Expanding disk style sensor is simple, effective, and closely tracks the dampness of landscaping
- Weight: (with wire) 7.0 oz.
- Length: 6 inches
- Switch Rating: 10.1 amps
- UL Listing: Class II Low Voltage (24 volt use only)
- Wiring: Normally closed contacts (closed when dry conditions)
- Includes 25 ft of #20 two conductor wire and mounting screws
-
502 PDF
| | The Mini-Clik II rain sensor is a simple, but effective way to prevent your sprinklers from coming on during or after rainfall. Based on our patented design, the Mini-Clik II is the most reliable and accurate rain sensor in the world. Each unit is constructed of high inpact thermoplastic and aluminum for years of trouble-free operation, even under harsh conditions. Simple click-stop settings accurately measure rainfall in quantities of 1/8" to one inch and shut off the system when turf has received the rainfall it needs. Reset rate is adjustable.
| |
|

Amseco / Kobishi America Inc
|
|---|
507-381BW
SPDT Reed Switch |
|
- Form C contacts (also known as SPDT).
- Make gap: 5/8"
- Break gap: 1 1/4"
- Max 30VDC 30VAC .25A 3W
| | Most reed switches are "normally closed" (the switch is closed when the magnet is near the switch.) Most security systems are wired with normally closed reed switches. Normally open switches are a bit more complicated to make, are a bit more expensive, and are normallynotused with security systems.
Normally open reed switches are useful for automation tasks. Connect the 507381BW to a PF284 PowerFlash controller and send a command to turn on a light when the garage door is open, or connect the 507381BW to home automation controllers such as
ActiveHomeor
HomeVision.
| |
|
CP-2
Cartell Driveway Sensors |

Specifications
- Power: 6-31 VAC or 8-46 VDC
- Standby Current: 950 microamps typ.
- Alarm Current: 15 millamps pulse
- Relay Rating: 2 amps @ 35VDC, 25 VAC maximum, SPST N.O., dry contact, mechanical relay
- Relay Trip Time: 2 Seconds
- Operating Temperature: -25°F to +125°F
- Dimensions: 1 5/8" dia. x 21 1/2" len.
|
- Detects moving vehicles (including motorcycles and snowmobiles).
- Operates gates.
- Direct burial system (eliminates vandalism).
- Free-exit sensor back from gate to prevent unauthorized entry.
- Covers 12' wide driveway from side of drive.
- Automatically directional when using 2 CP-2 units together.
- Totally self-contained sensing unit.
- Low power operation.
- Wide supply voltage.
- RFI/EMF protected.
- No earth grounding required.
- False alarm proof circuitry (pat. pending)
- Automatic internal diagnostic system.
- No outboard devices required.
- Installer selected trip mode.
- Available with 100' or 500' lead.
| |
|
CBCSM1
CURRENT SENSOR CONNECTING BLOCK |
|
- Allows the CSM1 Current Sensor to be used as a general purpose
current sensor (independent of the MRC44 or MRC88)
- Requires CSM1 Current Sensor and 781RG Power Supply
-
CBCSM1 Install PDF
| |
| |
|
CSM1
CURRENT SENSING MODULE |
|
- Senses the power state of a component by detecting the difference
in current drawn by the component when it is either on or off
- Used with the CBCSM1 for stand-alone applications
-
CSM1install PDF
| |
| |
|
SB2
Sump Bobber Float Switch |
| | Be warned if water level goes up or down out of tolerance! This low cost float switch features: High reliability, Sealed reed switch provides high isolation when pump wiring breaks down, Will operate totally submerged, unique reversible float allows for N.O. or N.C. switch circuit, fits virtually all sizes and types of return pipes. UL Listed at 1 AMP MAX at 24 VDC (recommended at <250mA). Comes complete with stainless steel hose clamp and 20 lead wire.
| |
|
|