HomeTech Solutions' Logo
TechNews
New product info and special deals.
Bookmark and Share
Your Order
View Cart
Checkout
Status
Login
LEARNING CENTER
Knowledge Base
Incredible selection. Credible help.
HOME
NEW PRODUCTS
SPECIALS
MOST POPULAR
SUPPORT
Products Manufacturers
Drapery Control Gift Ideas Weather & Clocks Xantech Specials
Low Price Guarantee Icon
Order:
888-257-4406
HomeTech Solutions Cupertino CA
Phone: 408-257-4406
Fax: 408-257-4389
Other Contact Info
Cable Coax DSL HDMI IR Leviton Plate Quickport Speaker Splitter Switch Video Wall Wire
Smoke Detectors
(10446)
Smoke and Heat Detectors




18xFPLR
Fire Alarm Cable,18 Ga, 2 Cond
You should use this special 'fire rated' cable to wire smoke and heat alarms. As well as runs to manual fire alarm pulls and fire alarm signals such as sirens,speakers, and flashers. Consult your local codes as they vary from area to area.
Hide
  • (ETL) US FPLR Rated
  • 75°C
  • 18 AWG
  • Countdown feet markings
  • Available by the foot or ezpull box
  • Bright red jacket
Loading real-time item data...

18/2FPLR 18/4FPLR 18/6FPLR

5604
Fixed Temperature Sensor
Rate-Of-Rise and fixed temperature heat detectors are not intended to replace smoke detectors as safety devices, but are for property protection only. They are useful in kitchens, where traditional smoke detectors false-trigger all too often. Connect as many as desired, in parallel, to an unused zone of your security system and set that zone up as a normally open fire zone. Single end-of-line resistor mode is strongly suggested for safety reasons.

The SR-5601P is the more common device. Use the SR-5604 in environmnents where the SR-5601P false-triggers.
Hide
  • 5601: Rate-of-Rise and fixed temp. (135 degrees) detector.
  • 5604: Fixed temp. detector. (198 degrees)
  • One circuit, normally open.
  • 6-125 VAC 3.0A
  • 6-28 VDC 1.0A
  • Coverage up to 30 x 30 feet
  • Designed to NFPA Standard 72
  • UL Listed.
  • California State Fire Marshal Listed
  • Approved Board of Standards and Appeals, NYC (MEA)
Loading real-time item data...

BK-5604 8.19BK-5601P

449CSTE
Smoke Detector,4-wire,
  • Photoelectric Smoke Alarm. No radioactive materiel!
  • Only for use with any normally closed security system zone.
  • Integral heat detector.
  • Self-diagnostics include automatic sensitivity testing.
  • Meets NFPA 72 field sensitivity testing requirements without the need of external meters.
  • FM Approved, UL Listed, California State Fire Marshal Approved, MEA (New York City) Approved.
  • Operates on 6-12VDC (449AT) or 12-24VDC (449CST) from security system.
  • LED status indicator.
  • Manual test via magnetic switch.
  • Integral sounder (449CST only).
  • Integral sounder and EOL Relay (449CSTE). See our tutorial on adding a smoke detector to a security system.
Hide
Loading real-time item data...

449AT ES-449CST 449CRT ES-449CSRH ES-449CSTE

25S
Smoke Detector Tester
  • Simple to use: 1 to 2 second spray will temporarily set of a smoke detector.
  • 200+ test bursts.
Hide
Loading real-time item data...

25S

429CST
Smoke Alarm,6/12V,2wire,heat
  • Photoelectric Smoke Alarm. No radioactive materiel!
  • Only for use with security systems with 2-wire smoke compatibility.
  • Integral heat detector.
  • Self-diagnostics include automatic sensitivity testing.
  • Meets NFPA 72 field sensitivity testing requirements without the need of external meters.
  • FM Approved, UL Listed, California State Fire Marshal Approved, MEA (New York City) Approved.
  • Operates on 6-12VDC (429AT) or 12-24VDC (429CST) from security system.
  • LED status indicator.
  • Manual test via magnetic switch.
  • Perfect for use with the DEST6100.
  • May use multiple 429AT's with the DEST6100 without tying up any of the 16 input zones!
  • Integral sounder (429CST only). See our tutorial on adding a smoke detector to a security system.
Hide
Loading real-time item data...

ES-429AT ES-429CST

CM15
Carbon Monoxide Sensor
  • Listed to UL Standard 2075 for carbon monoxide detectors.
  • Tested to UL Standard 2034 for carbon monoxide detectors.
  • Surface mounts to a wall over a single gang electrical box.
  • Flush mounts to the wall over a 4 X 4 or two gang electrical box.
  • Small, low profile, attractive unit in a white plastic case. It looks similar to a thermostat.
  • Detector alarms at multiple levels of exposure to carbon monoxide based on time weighted averages of the gas present.
  • Inexpensive, easy to install. Microcomputer control allows mostly automatic operation.
  • Test & Reset switch conducts internal tests and actuates relays.
  • Visual display: GREEN - Normal operation. FLASHING AMBER - Trouble Contact your installer or Macurco Tech Support RED - Danger! Move to fresh air (hazardous co
  • ndition is present.)
  • Solid state sensor. No maintenance or periodic sensor replacement needed.
  • SPDT Relay to connect to Alarm Control Panels or switch external alarm devices.
  • Normally closed SPST Trouble relay provides means for system-wide supervision.
Hide
Loading real-time item data...

MA-CM15

DS18S20
2 Pics
Digital Temperature Probe
  • Digital Temperature Sensor for Use With HVMF
  • Three Lead Package
  • So small you can stash it anywhere! Even paint it white and stick it through a tiny hole in the ceiling.
Hide
Loading real-time item data...

95B5945


In Business Since 1992 Icon Satisfaction Guarantee Icon Same Day Shipping Icon Privacy Policy Icon Low Price Guarantee Icon Tech Home Icon
site map | resale info | employment | contact us | SUPPORT
Text and images copyright © 1992-2009 HomeTech Solutions. All rights reserved.
[Sat 11/21/09 10:55:03 AM PST] Tiny HomeTech Logo HomeTech Solutions is UpFront