Smoke, Heat, & CO2 Detectors


Smoke Detectors
Photoelectric 2-Wire Smoke Alarms
Photoelectric 4-Wire Smoke Alarms
Smoke Detector Tester


Heat Detectors
Rate-Of-Rise & Heat Detectors

 
Carbon Monoxide Detectors
CO2 Detector


Smoke & Fire Alarm Wire
18 Gauge, 2 & 4 Conductor FPLR


Related Links
Security Index
Main Index

Smoke Detectors


429AT & 429CST
Photoelectric 2-Wire
Smoke Detectors
  • Photoelectric Smoke Alarm. No radioactive materiel!
  • Only for use with security systems with 2-wire smoke compatibility.
  • Integral heat detector.
  • Self-diagnostics include automatic sensitivity testing.
  • Meets NFPA 72 field sensitivity testing requirements without the need of external meters.
  • FM Approved, UL Listed, California State Fire Marshal Approved, MEA (New York City) Approved.
  • Operates on 6-12VDC (429AT) or 12-24VDC (429CST) from security system.
  • LED status indicator.
  • Manual test via magnetic switch.
  • Perfect for use with the DEST6100.
  • May use multiple 429AT's with the DEST6100 without tying up any of the 16 input zones!
  • Integral sounder (429CST only).

See our tutorial on adding a smoke detector to a security system.

ES-429AT
Smoke Alarm,6/12V,2wire,heat
For ordering information, please see this item on our current website.  
ES-429CST
SmkAlm,12/24V,2wire,heat,sound
For ordering information, please see this item on our current website.  


449AT 449CST 449CSTE
Photoelectric 4-Wire
Smoke Detectors
  • Photoelectric Smoke Alarm. No radioactive materiel!
  • Only for use with any normally closed security system zone.
  • Integral heat detector.
  • Self-diagnostics include automatic sensitivity testing.
  • Meets NFPA 72 field sensitivity testing requirements without the need of external meters.
  • FM Approved, UL Listed, California State Fire Marshal Approved, MEA (New York City) Approved.
  • Operates on 6-12VDC (449AT) or 12-24VDC (449CST) from security system.
  • LED status indicator.
  • Manual test via magnetic switch.
  • Integral sounder (449CST only).
  • Integral sounder and EOL Relay (449CSTE).

See our tutorial on adding a smoke detector to a security system.

ES-449AT
Smoke Detector,4-wire,
Power 6-12
For ordering information, please see this item on our current website.  
ES-449CST
SmkAlm,12/24V,4wire,heat,sound
For ordering information, please see this item on our current website.  
ES-449CSTE
SmkAlm,12/24V,4wire,heat,
Sound and EOL Relay
WHILE SUPPLIES LAST!!!
For ordering information, please see this item on our current website.  


HomeTech Solutions
25S
Smoke Detector Tester
  • Simple to use: 1 to 2 second spray will temporarily set of a smoke detector.
  • 200+ test bursts.
GC-25S
Smoke Detector Tester
2 1/2 oz spray can
For ordering information, please see this item on our current website.  


This is the old HomeTech Solutions website.
Please visit our new website here

Rate-Of-Rise Heat Detectors


HomeTech Solutions
5601P
5604

Rate-Of-Rise & Heat Detectors
  • 5601: Rate-of-Rise and fixed temp. (135 degrees) detector.
  • 5604: Fixed temp. detector. (198 degrees)
  • One circuit, normally open.
  • 6-125 VAC 3.0A
  • 6-28 VDC 1.0A
  • Coverage up to 30 x 30 feet
  • Designed to NFPA Standard 72
  • UL Listed.
  • California State Fire Marshal Listed
  • Approved Board of Standards and Appeals, NYC (MEA)
  • Information Sheet (PDF)
Rate-Of-Rise and fixed temperature heat detectors are not intended to replace smoke detectors as safety devices, but are for property protection only. They are useful in kitchens, where traditional smoke detectors false-trigger all too often. Connect as many as desired, in parallel, to an unused zone of your security system and set that zone up as a normally open fire zone. Single end-of-line resistor mode is strongly suggested for safety reasons.

The SR-5601P is the more common device. Use the SR-5604 in environmnents where the SR-5601P false-triggers.

SR-5601P
Rate-of-Rise Temp Sensor
Plus 135 degree fixed
For ordering information, please see this item on our current website.  
SR-5604
Fixed Temperature Sensor
194 degree fixed
For ordering information, please see this item on our current website.  


This is the old HomeTech Solutions website.
Please visit our new website here

Carbon Monoxide Detectors


HomeTech Solutions
CM15
Carbon Monoxide Detector
  • Listed to UL Standard 2075 for carbon monoxide detectors.
  • Tested to UL Standard 2034 for carbon monoxide detectors.
  • Surface mounts to a wall over a single gang electrical box.
  • Flush mounts to the wall over a 4 X 4 or two gang electrical box.
  • Small, low profile, attractive unit in a white plastic case. It looks similar to a thermostat.
  • Detector alarms at multiple levels of exposure to carbon monoxide based on time weighted averages of the gas present.
  • Inexpensive, easy to install. Microcomputer control allows mostly automatic operation.
  • Test & Reset switch conducts internal tests and actuates relays.
  • Visual display: GREEN - Normal operation. FLASHING AMBER - Trouble Contact your installer or Macurco Tech Support RED - Danger! Move to fresh air (hazardous condition is present.)
  • Solid state sensor. No maintenance or periodic sensor replacement needed.
  • SPDT Relay to connect to Alarm Control Panels or switch external alarm devices.
  • Normally closed SPST Trouble relay provides means for system-wide supervision.
GC-CM15
Carbon Monoxide Sensor
For ordering information, please see this item on our current website.  


This is the old HomeTech Solutions website.
Please visit our new website here

Smoke & Fire Alarm Wire


HomeTech Solutions
182FPLR
184FPLR

18 Gauge, 2 & 4 Conductor Smoke & Fire Alarm Wire, FPLR
  • (ETL) US FPLR Rated
  • 75°C
  • 18 AWG
  • Countdown feet markings
  • Available by the foot or ezpull box
  • Bright red jacket
You should use this special "fire rated" cable to wire smoke and heat alarms. As well as runs to manual fire alarm pulls and fire alarm signals such as sirens, speakers, and flashers. Consult your local codes as they vary from area to area.
HT-182FPLR
Fire Alarm Cable,18 Ga, 2 Cond
Solid,Red,FPLR,NEC760,CMP/FT4
Calif. State Fire Marshal
For ordering information, please see this item on our current website.  
HT-184FPLR
Fire Alarm Cable,18 Ga, 4 Cond
Solid,Red,FPLR,NEC760,CMP/FT4
Calif. State Fire Marshal
For ordering information, please see this item on our current website.  


This is the old HomeTech Solutions website.
Please visit our new website here

Copyright © 1992-2008 HomeTech Solutions. All Rights Reserved.